ETS-Lindgren HI-6153 Electric Field Probe User Manual
Page 106
106
|
Operating Protocols
Probe
Command
Description
Probe Response
D3
Read probe data
:Dx.xxxyy.yyzzz.zB
xxxx, yyyy, zzzz=
4-digit axis values with
floating decimal point
B=battery flag, N or F
D5
Read probe data
:Dx.xxxyy.yyzzz.zcccc.B
xxxx, yyyy, zzzz=
4-digit axis values with
floating decimal point
cccc=composite field value
with floating decimal point
B=battery flag, N or F
I
Identification command
:I60XX
XX=specific probe model
sr=10-character software
revision
sn=8-character serial
number
cd=8-character calibration
date
B=battery flag, N or F
The Identification command,
I, may also be used as the first command
sent. The command will turn on the laser. Once communication
between the probe and the Laser Data Interface (LDI) is established,
the return string will be sent. Subsequent
I commands immediately
send the return string.
TC
Read temperature in
Centigrade
:Txxxx.