STEP #9 INSTALLING GLASS STOPS
STEP #8 CLEANING THE GLAZING TRACK
FIGURE #8
3.
2.
1.
FIGURE #9
STEP #7 SETTING BLOCKS APPLICATION
SECTION VII: GLAZING AND REGLAZING DOORS
PAGE 10
The glass stops are designed to be inserted into the glazing tabs in the door rails and then
rotated down to lock into place. See Figure #9. Use a soft faced mallet, if needed. Hit on
the corner of the glass stop, making sure not to distort the metal. Start at one end and
work toward the other end of the glass stop.
Check to ensure that the glazing surface of the door and glazing bead are free from metal
shavings. Metal shavings may be blown out with air or brushed out. See Figure #9.
Insert three (3) setting blocks (#H348 or #H159) at approximately 6" from the inside
corners. Setting blocks are used at the door stiles and the bottom rail only. An adjustable
jack screw will be used at the top rail. Refer to Figure #1 on page 8. If required, apply
silicone to the back of the setting blocks to keep them in the correct position until the
glass is installed. See Figure #8.
LOCK STILE
6"
DPS/BB JULY 2000
6"
GLAZING
TRACK
PIVOT EDGE
SETTING
BLOCK
ADJUSTABLE
JACK SCREW