PROJECT SHOP DRAWINGS.

BLOCK EVEN WITH THE
FRONT OF THE MULLION

POSITION THE SETTING

TONGUE.

9/2000

bite should be 9/16" in a 2 1/2" wide system. Push the infill completely
back against the interior gaskets.

POSITION THE ANTIWALK

OF THE VERTICAL GLASS
OPENING. SILICONE THE

INSTALLED.

AFTER THE GLASS IS

BLOCK INTO POSITION

BLOCK AT THE CENTER

THE HORIZONTAL SETTING BLOCKS
MUST BE POSITIONED AT 1/4
POINTS OR AS SPECIFIED IN THE

Verify that all gasket retainer pockets are free from dirt and foreign
matter. Place the specified setting blocks and antiwalk blocks as shown in
the approved project shop drawings. Set the specified glazing infill into
the corresponding opening, ensuring positive bearing on the setting blocks
and an equal glass bite at all sides of the infill panel. The typical glass

SECTION VII: GLAZING INSTALLATION

STEP #1 INSTALL GLAZING MATERIALS