Room layout-model 200ip/250ip dyno, P/250 – Dynojet 250ix: Pre-Installation Guide User Manual
Page 23
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Model 200iP/250iP Dynamometer
Version 3
Pre-Installation Guide for Model 200i/250i, 200iP/250iP, 250iX, and 250iPX Motorcycle Dynamometers
15
R
OOM
L
AYOUT
—M
ODEL
200
I
P/250
I
P D
YNO
Use the following information to locate the necessary dyno equipment, power outlets,
compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit
specifications (P/N 98229102) you received from your salesman.
Note: The pit must be provided with exhaust ventilation at a rate of not less than
1CFM per ft.
2
of floor area (26CFM for the 250iP pit) taken from a point 300 mm
(12 in.) off the floor of the pit at all times that the building is occupied or when
vehicles are parked over this area.
Figure 8: Room Layout—Model 200iP/250iP Top View
Pd186
284.48 cm (112.00 in.)*
121.92 cm
(48.00 in.)
60.96 cm (24.00 in.)
min. dimension
standard carriage
177.39 cm
(69.84 in.)
31.09 cm
(12.24 in.)*
29.84 cm (11.75 in.)*
60.33 cm (23.75 in.)*
standard carriage
320.04 cm
(126.00 in.)*
standard carriage
345.44 cm
(136.00 in.)*
min. dimension
extended carriage
220.98 cm
(87.00 in.)
extended carriage
365.76 cm
(144.00 in.)*
extended carriage
436.88 cm
(172.00 in.)*
*Dimensions are given for reference only and will vary with room size.
provide compressed air for the:
•optional air brake
•optional AFR‐4 pump
provide an outlet for dyno power