Options, Specifications – Code 3 V-Con Siren User Manual
Page 14

14
Options
SirenLock
TM
(L4 and L6 Models Only)- An interlock circuit between the siren and the light control circuits that permits automatic siren
tones only when the progressive switch is in Level 3 or in Level 2 or 3 (user selectable - works in conjunction with the horn transfer
relay). This feature is used in jurisdictions that
require warning lights to be on before the siren is activated.
InterClear
®
This unique feature can be used to activate additional warning lights for 7 seconds when in an Hit-N-Go override or "
scrolling " by pushing a single button or the vehicle horn ring, thus allowing an additional level of warning in situations such as inter-
sections without the operator having to take his hands off the wheel or his eyes off the road.
Pluggable Microphone - A plug-in microphone jack in lieu of the standard wired-in microphone may be specified. A plug-in noise-
canceling microphone must be ordered seperately if needed.
Specifications
Siren Section
Input Voltage - 10 to 16 VDC, negative ground (earth).
(Note: Operation above 14 VDC for an extended period of time may result in speaker damage.)
Operating Current: 5 Amps @ 13.6V with 19-ohm load ( 58 W Spkr )
8 Amps @ 13.6V with 11-ohm load ( 1 - 100 W Spkr )
16Amps @ 13.6V with 5.5-ohm load ( 2 - 100 W Spkrs )
Standby Current: 18 mA excluding backlighting
Cycle Rate:
WAIL - 11 cycles/minute.
YELP - 200 cycles/minute.
Voltage Output ( approx. ) 64 V peak-to-peak
Audio Section
Audio Response: 3 dB down points - 500 to 3000 hz.
1000 hz. 0 dB Reference
Audio Distortion: 10% or less below clipping.
Lighting Section ("L4" Models Only)
Warning Light Control: Progressive switching, 3 levels
30 Amps. maximum combined total for Levels 1,2 & 3
Level 1
30A maximum
Green LED Indication
Level 2
30A maximum
Yellow LED Indication
Level 3
30A maximum
Red LED indication.