Ac electrical characteristics, Electrical characteristics – Cypress Perform CY7C1413BV18 User Manual
Page 21
CY7C1411BV18, CY7C1426BV18
CY7C1413BV18, CY7C1415BV18
Document Number: 001-07037 Rev. *D
Page 21 of 30
I
DD
V
DD
Operating Supply
V
DD
= Max,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
CYC
200MHz
(x8)
620
mA
(x9)
620
(x18)
655
(x36)
715
167MHz
(x8)
535
mA
(x9)
535
(x18)
565
(x36)
615
I
SB1
Automatic Power down
Current
Max V
DD
,
Both Ports Deselected,
V
IN
≥ V
IH
or V
IN
≤ V
IL
f = f
MAX
= 1/t
CYC
,
Inputs
Static
300MHz
(x8)
370
mA
(x9)
370
(x18)
370
(x36)
400
278MHz
(x8)
355
mA
(x9)
355
(x18)
355
(x36)
370
250MHz
(x8)
355
mA
(x9)
355
(x18)
355
(x36)
370
200MHz
(x8)
300
mA
(x9)
300
(x18)
300
(x36)
300
167MHz
(x8)
270
mA
(x9)
270
(x18)
270
(x36)
270
AC Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
+ 0.2
–
–
V
V
IL
Input LOW Voltage
–
–
V
REF
– 0.2
V
Electrical Characteristics
(continued)
DC Electrical Characteristics
Over the Operating Range
[14]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit