10. AC ADAPTOR

(1)

Input voltage

100V ~ 240V AC (50/60 Hz)

(2)

Input current

250 mA

(3)

Rated output

9V ±5%

(4)

Efficiency

65% or more (AC 100V/50 Hz full load)
70% or more (AC 240V/50 Hz full load)

(5)

Ripple and noise voltage

Less than 150 mVp-p (9 VDC)

(6)

Insulation test

More than 100M ohm
(DC 500V, 1 minute, between primary and secondary circuit and chassis)

(7)

Leakage current

0.25 mA or less (AC 240V/50 Hz)

(8)

Temperature rise

45K or less on case surface (100 VAC/50 Hz full load @25°C)

(9)

Over voltage protection

120% - 150%

(10) Overload protection current

1.8 - 3.5A (AC 100-240, 25°C)

(11) No load power consumption

3W or less (AC 240V, 25°C)

(12) Safety standard

UL, C-UL, PSE (10AD-JU)
VDE, GS, CE (10AD-E)

(13) Size

10AD-JU - 75 mm (L) × 50 mm (W) × 30 mm (H)

(14) Case material

94V-1

(15) Cable

1828.8 mm UL2468#22 × 2C

(16) Plug

3.5 Ч 1.3 Ч 9.5S

(17) Polarity

Center ”+”

(18) Weight

104 g ±5g

11. EMI STANDARD

VCCI Class B
FCC Class B
EN55022