beautypg.com

Esc \ n1 n2 – Citizen Systems Model CMP-10 User Manual

Page 36

background image

— 34 —

ESC \ n1 n2

[Function]

Specifying the relative positions

[Code]

<1B>H<5C>H

[Range]

{0 =< n1 =< 255}

{0 =< n2 =< 255}

[Outline]

The printing start position is specified in the number of dots (1/203 inch unit) from
the current position.

• Rightward direction is taken as plus and leftward direction as minus.

• To specify N dot in minus (left) direction, use a complement of N for assignment.

• N dots = 65536 – N

• The number of dots is divided by 256, whose quotient is taken as n2 and the residual

as n1.

[Caution]

Specifying exceeding the top of line or the end of line is ignored.

[See Also]

ESC $

[Sample Program]

See Sample Program and Print Results for ESC $.

ESC _

[Function]

Setting the printer in default state

[Code]

<1B>H<5F>H

[Outline]

Sets the printer in default state. The default state is as follows:

• All printing attributes like underline, rotating etc. are cleared.

• Internal font A (12 × 24) is selected.
• Pitch between lines is 1/6 inch.

• Pitch between characters is 0.

• Barcode height is 162 dots, and barcode width is 3.

• All downloaded fonts and bit images are cleared.

• Print density is 100%.

• Communication speed is set to 9600 bps.

• Auto power-off time is set at 5 min.

• Memory switch is set to “all 0”.

[See Also]

ESC @