beautypg.com

Taylor-Wharton EasyCarb User Manual

Page 7

background image

7

8.

Attach the two 90

o

elbow compression unions to the tubing ends coming through

the wall and direct them toward the fill/vent lines.

9. Carefully unload the easycarb™ tank and move it to its permanent position. It is
recommended that you securely anchor the top of the container to the wall or building
structure with a suitable bracket that clamps the top handling ring.

WARNING:
Be careful to properly connect the vent and fill lines to the box. If the vent line
is accidentally connected to the fill connection, the container relief device may
be blocked, which will create a dangerous pressure build-up in the lines or the
container

.

10. Route and mount both lines using ½ in. (12.7 mm) O.D. lines inside the building ,

until they reach the easycarb™ tank. Be sure to comply with all local building
codes.

11. Cut the vent line to final length and connect it to the elbow fitting on the vent tube

leading to the outside box.

12. Go to the container end of the vent line and test the line before attaching to the

container by blowing through the line to confirm that is unrestricted.

13. Cut fill line to final length, couple it to the remaining fill box elbow, then connect it

to the LIQUID connection on the easycarb™.

14. Apply the easycarb™ decal to the front of the container and post carbon dioxide

storage identification in the general area as required by local code.

Leak Checking the Installation

Open the LIQUID valve and close the USE and PB valves. Pressurize the system to
150 psig (10 bar/1034 kPa) with gaseous CO2 through the fill connection. Leak test
all joints using only approved leak test solutions. Follow the manufacturer’s recom-
mendations. Snoop Liquid Leak Detector is one approved solution; it is available
from: Nupro Co. 4800 E. 345

th

St. Willoughby, Ohio 44094. Leak test all connections.

If leaks are found, isolate the leaking plumbing from the tank pressure so all pressure
may be released from the area under repair.

WARNING:
In case of any downstream leaks to the point of use, close the USE Valve and
the PB Valve. Closing these valves will stop the flow of gaseous CO

2

to the

Supply Line Regulator and downstream piping so that repairs can be made to
any leaks.

Supply Line Installation

1.

Fill the easycarb™ using the filling procedure on page 7.

2.

Install a gas supply line from the Supply Line connector, on the easycarb™ to the
use point and finger tighten.

Note:
Liquid connection fitting must
be assembled to liquid line
using pipe thread sealant,
such as teflon tape, prior to
attaching the liquid line
connection.

Note:
After completing the tank
installation, fill out the
easycarb™ Warranty Card