TROUBLESHOOTING

Symptom

Possible Cause

Corrective Action

Frost on bottom of
easycarb™

1. Frost may appear

during periods of
high use – this is
normal

2. Leak in beverage

system.

1. None

required.

2. Repair

leak.

Frost on bottom of
easycarb

and

Pressure over125 psig
(8.6 bar/862 kPa)

Pressure Building circuit
incorrectly adjusted.

Readjust regulator (See
Maintenance Section).

Frost on easycarb™
and container is
noticeably cold over
entire outer surface.

Loss of container
vacuum.

See “Checking Container
Performance” in Maintenance
Section.

Low supply pressure -
Container level gauge
shows zero

Out of CO

2

Call supplier for fill.

Low supply pressure –
easycarb™ pressure
OK.

1. Supply line regulator

incorrectly set.

2. Supply line leaking
3. USE valve on tank

closed

4. Leak in beverage

system.

5. Restriction in gas

supply line.

1. Reset to 90 psig (6.2

bar/621 kPa) or required
supply Pressure.

2. Repair

leak.

3. Open

Valve.

4. Repair

leak.

5. Close USE and PB valve

and open beverage line at
a convenient point to
isolation restriction.

Low tank pressure –
below 125 psig (8.6
bar/862 kPa)
No frost on unit.

1. Pressure

building

circuit set too low.

2. Isolation

valves

closed.

1.

Readjust regulator ( See
Maintenance Section).

2.

Open USE valve and
P.B.

valve. Handle should be
parallel with line.

High carbon dioxide
consumption.

Leak in system.

Repair leaks.

easycarb™ won’t fill.

1. LIQUID valve closed

2. Tank already full.
3. Delivery

vehicle

pressure too low.

1. Open valve. Handle

should be parallel with fill
line.

2. None

required.

3. Determine cause and

restore pressure.