Operations, Withdrawing product, Withdrawing liquid – Taylor-Wharton Microbulk Tanks User Manual

Page 19: Changing gas service, Withdrawing product 17, Withdrawing liquid 17, Changing gas service 17

background image

TW-407 Rev.-

17

Withdrawing Product

External Vaporizer

To withdraw product from the MICRO BULK, connect a suitable vaporizer to the vaporizer inlet con-

nection (CN-4). Equip the vaporizer with a relief valve sized in accordance with the vaporizer manufac-

turer’s recommendations. Install a line regulator downstream of the vaporizer. Connect the outlet of

the regulator to the application. Follow these steps:

1.

Open the pressure building valve (V-6). Monitor the pressure gauge (PI-1). When the pressure ex-

ceeds the desired delivery pressure, continue.

2.

Open the vaporizer inlet valve (V-4).

3.

Adjust the line regulator to desired delivery pressure.

Withdrawing Liquid

Attach a transfer hose from the receiver vessel to the MICRO BULK liquid connection (CN-3) and open

the adjacent liquid valve (V-3). The pressure in the container will drive liquid product out through the

valve as long as the container pressure exceeds that of the receiver.

Changing Gas Service

The MICRO BULK changed for the following gas only; argon, oxygen, or nitrogen service. A tank that
has been used for CO

2

cannot be switched to another service. Follow these steps to properly change

gas service:

1

Safely empty all liquid from the container.

2

Open the pressure building inlet and outlet valves (V-6 and V-7) and the vent valve (V-2) to vaporize

any residual liquid that may remain in the bottom of the vessel. It may require an hour or longer to

vaporize all the residual liquid.

3

To ensure purity, it is recommended that the MICRO BULK be evacuated with a suitable vacuum

pump. The ultimate vacuum reading should be at least 20 inches

of mercury.

4

Replace the fittings for the liquid, top fill, and use connections with the appropriate fittings shown

in the chart below. Use Teflon tape or another suitable thread sealant when threading the fittings

into the connections.

5

Remove any decals identifying the previous gas service. Attach new gas service identification

decals.

Before disconnecting fill hose from fill connection (CN-1) open fill purge valve to discharge product

from fill hose. After this operation is complete close fill purge valve then disconnect hose from (CN-1).

OPERATIONS