beautypg.com

Pressure building circuit, Pressure building circuit 11 – Taylor-Wharton Microbulk Tanks User Manual

Page 13

background image

TW-407 Rev.-

11

Pressure Building Circuit

The pressure building circuit serves to build pressure after filling the vessel. The circuit is also used

to ensure sufficient driving pressure during high product withdrawal periods. Opening the pressure

building outlet valve (V-6) and pressure building inlet valve (V-7) permits the circuit to function. When

the pressure inside the vessel drops below the pressure builder setting, the pressure building regulator

(PCV-1) opens. This creates a path from the liquid in the bottom of the container to the gas space in

the top. This path contains an external pressure building coil (PBC-1) to vaporize product as it flows

from the bottom to the top of the vessel. Liquid is expanded to a vapor and pressure is increased in

the vessel.

Figure 4: Pressure building circuit highlighted

PBC-1

PCV-1

S-1

CN-6

V-7

SV-3

Pressure Building Circuit