Power Supply: OptiPlex GXi

DC Voltage Ranges

|

DC Power Cables (Low-Profile Chassis)

|

DC Power Distribution (Low-Profile Chassis)

|

DC Power Cables (Midsize Chassis)

|

DC Power

Distribution (Midsize Chassis)

|

DC Power Cables (Mini Tower Chassis)

|

DC Power Distribution (Mini Tower Chassis)

DC Voltage Ranges

The low-profile chassis has a 145-W system power supply, whereas the midsize and mini tower chassis have a 200-W system power supply. The system power
supplies can operate from an AC power source of 115 VAC at 60 Hz or 230 VAC at 50 Hz. The system power supplies provide the DC operating voltages and
currents listed in the table below.

 

1

The combined load on the +5-VDC and +3.3-VDC outputs cannot exceed 105 W on the low-profile computer or 140 W on the midsize and mini tower

chassis.

2

Withstands surges of up to 11.0 A to support disk start-up operations.

3

VFP (volts flea power) — sometimes called "standby power."

DC Power Cables (Low-Profile Chassis)

NOTE: Each power supply produces DC voltages only under its loaded condition. Therefore, when you measure these voltages, the DC power
connectors must be connected to their corresponding power input connectors on the system board or drives.

Voltage

Range

Maximum Output Current

+3.3 VDC

+3.15 to +3.45 VDC

12.0 A

1

(low-profile chassis)

14.0 A

1

(midsize and mini tower

chassis)

+5 VDC

+4.75 to +5.25 VDC

18.0 A

1

(low-profile chassis)

22.0 A

1

(midsize and mini tower

chassis)

+12 VDC

+11.40 to +12.60 VDC

3.0 A

2

(low-profile chassis)

6.0 A

2

(midsize and mini tower chassis)

-12 VDC

-10.80 to -13.20 VDC

0.3 A

-5 VDC

-4.50 to -5.50 VDC

0.3 A

+5 VFP

3

+4.75 to +5.25 VDC

10 mA