Task 2: changing the ip address, Using the cmc cli to set the ip address – Dell POWEREDGE M1000E User Manual
Page 17

Dell 8/4Gbps FC SAN Module Hardware User’s Manual
15
53-1001964-01
Modify the FC SAN Module IP address
2
e. From the COM Port Properties window, select the following configuration values:
•
Bits per second: 9600
•
Databits: 8
•
Parity: None
•
Stop bits: 1
•
Flow Control: None
For LINUX or UNIX
a. Enter the following at the command prompt:
tip /dev/ttyb -9600
b. When the terminal application stops reporting information, press Enter to display the login
prompt.
c. Log in to the default administrative account using the following identification:
Login: admin
Password: password
d. When prompted either change the administrative password, or press Ctrl-C to bypass.
Task 2: Changing the IP address
1. Verify that the FC SAN Module has completed POST. When POST is complete, the port status
and FC SAN Module power and status LEDs return to a standard healthy state.
2. Enter the CLI ipAddrSet command.
Follow on-screen instructions and supply the correct information, as shown in the following
example.
switch:admin> ipaddrset
Ethernet IP Address [10.77.77.77]:10.32.53.47
Ethernet Subnetmask [255.255.255.0]:255.255.240.0
Fibre Channel IP Addresss [none]:
Fibre Channel Subnetmask [none]:
Gateway IP Address [0.0.0.0]:10.32.48.1
DHCP [Off]:
IP address is being changed...Done.
3. Enter ipAddrShow at the prompt to verify that the address was correctly set.
Using the CMC CLI to set the IP address
Use the following steps to connect modify the FC SAN Module IP address through the CMC CLI.
1. Establish a Telnet session to the CMC CLI.