Closed with Code Change in Fabric OS v6.4.1
This section lists the defects with Critical, High and Medium Technical Severity closed with a code change as of
October 7, 2010 in Fabric OS v6.4.1.
Defect ID: DEFECT000319291
Technical Severity: Critical
Summary: In a dual Inter-fabric Link (IFL) FCR fabric with LSAN Matrix configured and LSAN binding
enabled, disabling the EX_Port for one of the IFLs causes all FCR devices to be removed
from the name server database.
Symptom: In an FCR fabric with LSAN Matrix configured, if there are two IFLs from a FCR to one edge
fabric and LSAN binding is enabled, then when one of the EX_Ports is disabled, all imported
devices corresponding to this edge fabric are dropped from name server.
Feature: 8G FCR
Function: FCR Daemon
Probability: Low
Found in Release: FOS6.4.0
Service Request ID: 451063
Defect ID: DEFECT000319434
Technical Severity: Critical
Summary: Originator source ID sent by FCR in the header and in the body of the TAPE REC command
frame do not match. This causes the command to fail.
Symptom: The Tape REC command fails in an FCR environment, causing corrupted data on the tape.
Feature: 8G FCR
Function: FCR Daemon
Probability: High
Found in Release: FOS6.4.0
Service Request ID: 450651
Defect ID: DEFECT000319598
Technical Severity: Critical
Summary: Functional fans are flagged as bad with error code "[PLAT-5042], FAN I2C reset” messages
in the Raslog.
Symptom: One or more fans go into a faulted state on the DCX chassis even though the fans are
operating properly.
Workaround: Reseat the fan reported as faulty.
Feature: System Controls/EM
Function: Infrastructure
Probability: Medium
Found in Release: FOS6.4.0
Service Request ID: 451479