Defect ID: DEFECT000307117

Technical Severity: Medium

Summary: Unable to form an ISL with AP7420 platform

Symptom: A switch running FOS6.4.0 cannot form an ISL with AP7420 platform

Workaround: Connect AP7420 to a platform that is running an earlier release of FOS than FOS6.4.0

(e.g. FOS6.3.0).

Feature: FC Services

Function: Fabric

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000308461

Technical Severity: Medium

Summary: Error in thresholding logic for port state change events prevents thresholding condition

from being reported properly.

Symptom: Fabric watch does not detect the condition and generate the correct warning messages for

port thresholding events. Customer only sees SNMP-1008 messages indicating "...Last
device change happened at HH:MM:SS..." but no thresholding event indicating the count is
above the threshold.

Feature: FABRIC WATCH

Function: CLI

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000308734

Technical Severity: Medium

Summary: Backup/Restore job fails with FICON tape read extension

Symptom: Restore job fails with invalid record id

Workaround: Disable / don't enable FICON emulation for tape jobs

Feature: FCIP

Function: FCIP I/O

Probability: Medium

Found in Release: FOS6.4.0

Defect ID: DEFECT000312245

Technical Severity: Medium

Summary: Path not brought online after path deactivation/reactivation in a large heavily loaded FICON

tape emulation configuration

Symptom: Unable to vary paths back online after offline.

Workaround: When FICON path control blocks are stuck at invalid state, disable the tunnel. If issues

are occurring with FICON emulation and ESCON devices, disable FICON Emulation. In the
case of the failed tape job, resubmit it.

Feature: FCIP

Function: Emulation

Probability: Medium

Found in Release: FOS6.4.0