beautypg.com

Dell POWEREDGE M1000E User Manual

Page 60

background image

Closed with Code Change in Fabric OS v6.4.0a

Fabric OS v6.4.1 Release Notes v1.0

Page 60 of 62

Defect ID: DEFECT000281212

Technical Severity: Medium

Summary: In AG mode, N-Port failover results in F-Ports with attached hosts getting stuck as G_Port

Symptom: F-Ports get stuck as G-Ports after AG N-Port failover.This happens when there is a change in

the base address for the N-Port due to failover, or when there is no wwn-area mapping for
few devices and due to the login sequence of these devices, the PIDS assigned conflicted
with the already allocated PID to another device, resulting in the F-Ports getting stuck as G-
Port.

Workaround: portdisable/enable

Feature: Embedded Platform Services

Function: Other

Probability: Medium

Found in Release: FOS6.2.0_bc

Defect ID: DEFECT000286529

Technical Severity: Medium

Summary: FICON: when CHPs are very busy, CUP may report many IFCCs

Symptom: IFCCs on CUP exchange

Feature: Field Escalation

Function: FICON

Probability: Low

Found in Release: FOS6.3.0

Defect ID: DEFECT000288968

Technical Severity: Medium

Summary: When running 200 ms delay and 1% packet loss, after 4 days of run time, an IPSec

enabled FCIP circuit bounced.

Symptom: Tunnel bounce can occur.

Feature: FCIP

Function: FCIP Port

Probability: Low

Found in Release: FOS6.4.0

Defect ID: DEFECT000289418

Technical Severity: Medium

Summary: Tape drives fail when running over FCR with EX ports in Open mode. The REC accept

payload is incorrect.

Symptom: If host to tape I/O traverses FCR and includes an edge fabric, the tape drives would run for

a bit and then fail due to REC ACC is not processed correctly if EX port is operating in
IM3/Open mode.

Feature: Legacy FCR - 7500/FR4-18i

Function: FCR Daemon

Probability: High

Found in Release: FOS6.3.0

Service Request ID: 419137