Step 8: (optional) set up in-band management – Dell PowerVault MD3220i User Manual
Page 74
74
Appendix—Manual Configuration of iSCSI
Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see "Step 1: Discover the Storage Array (Out-of-
band Management Only)" on page 56) is the recommended method for
managing the storage array. However, to optionally set up in-band
management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference:
Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101
Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101
Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102
Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE:
The management station you are using must be configured for network
communication to the same IP subnet as the PowerVault MD32xxi host ports.
1 Establish an iSCSI session to the PowerVault MD3200i RAID storage array.
2 Restart the SMagent service.
3 Launch MDSM.
If this is the first storage array to be set up for management, the
Add New
Storage Array window is displayed. Otherwise, click New.
4 Select Manual and click OK.
5 Select In-band management and enter the host server name(s) or IP
address(es) of the host server that is running the PowerVault MD Storage
Manager software.
6 Click Add.
In-band management should now be successfully configured.
book.book Page 74 Sunday, September 11, 2011 10:24 PM