beautypg.com

Dell POWEREDGE M1000E User Manual

Page 30

background image

Fabric OS v7.1.0a Release Notes v1.0

Page 30 of 41

Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8

(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications

in the 8510-8 Backbone Hardware Reference Manual)

Configured

Number of Ports

Blades

Type of Blade

DCX 8510-8

@110 VAC

(Redundant

configurations)

DCX 8510-8

@200-240 VAC

(Redundant

configurations)

Comments

336 8Gb ports +
QSFP ICLs

FC8-48E

(Maximum of
seven FC8-48E
blades, with one
empty port blade
slot)

Port Blade

4 Power Supplies

2 Power
Supplies

200-240VAC: 1+1
Power Supplies
110VAC: 2+2

1

Power Supplies
Max 7 FC8-48E port
blades

384 16Gb ports +
QSFP ICLs

FC16-32, FC16-48

Port Blade

Not Supported

4 Power
Supplies

200-240VAC:
For DCX 8510-8, four
(2+2)

1

220V AC Power
Supplies are required

384 8Gb ports +
QSFP ICLs

FC8-32E, FC8-48E

Port Blade

Not Supported

4 Power
Supplies

200-240VAC:
For DCX 8510-8, four
(2+2)

1

220V AC Power
Supplies are required

Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs

FC16-32, FC16-48,
FC8-64, FC8-32E,
FC8-48E, FS8-18,
FX8-24

Intelligent
Blade
/Combination

Not Supported

4 Power
Supplies

For DCX 8510-8, four
(2+2)

1

220V AC Power
Supplies are required
when any special
purpose blade are
installed

Table 4 Power Supply Requirements for DCX 8510-8

Notes:

1. When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for

switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this
value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing
power supplies is incorrectly set to zero (Defect 000349586), which will prevent Fabric Watch from generating
notifications when the switch enters the marginal state due to missing power supplies