Fabric OS v7.1.0a Release Notes v1.0

Page 28 of 41

Power Supply Requirements for Blades in DCX/DCX-4S

Blades

Type of Blade

DCX/DCX-4S

@110 VAC

(Redundant

configurations)

DCX/DCX-4S

@200-240 VAC

(Redundant

configurations)

Comments

FC10-6

1

, FC8-

16, FC8-32,
FC 8-48, FC8-
64

Port Blade 2 Power

Supplies

2 Power Supplies

Distribute the Power Supplies
evenly to 2 different AC
connections for redundancy.

FR4-18i

1

Intelligent
Blade

Not Supported 2 Power Supplies

FS8-18,
FX8-24,
FCOE10-24

Intelligent
Blade

Not Supported DCX: 2 or 4 Power

Supplies

DCX-4S: 2 Power
Supplies

For DCX with three or more
FS8-18 Blades, (2+2)
220VAC Power Supplies are
required for redundancy.

For DCX with one or two
FS8-18 Blades, (2) 220VAC
Power Supplies are required
for redundancy.

For DCX-4S, (2) 220VAC
Power Supplies provide
redundant configuration
with any supported number
of FS8-18 Blades.

For both DCX and DCX-4S
with FX8-24 blades, (1+1)
220VAC Power Supplies are
required for redundancy.

Table 3 Power Supply Requirements for DCX and DCX-4S

1. Note that FC10-6 and FR4-18i are not supported with FOS v7.1 or later