background image

28

Troubleshooting

Physical Disk Related Issues

Configuration Utility Error Messages

NOTE:

These error messages are displayed inside the Configuration Utility. Restart your system and retry if you

encounter any of these.

Table 6-2.

Physical Disk Issues

Problem

Suggested Solution

The system does not boot from the SAS 5 HBA.

Ensure that the boot disk is attached to the adapter at the
lowest ID and check the adapter and physical disk boot order
in the system BIOS.

NOTE:

See your system documentation for information about

boot device selection.

Fatal errors or data corruption are reported in the
System Event Log by the operating system when
accessing physical disks.

See "Getting Help" on page 35.

Physical disk is not enumerated during POST.

• Go to the Configuration Utility and ensure that the drive is

not enumerated in the SAS topology.

• Verify the cable connection.
• Reseat the drive.
• Check the cable for damage.

Table 6-3.

Configuration Utility Error Messages

Message

Meaning and Suggested Solution

An error occurred while reading

non-volatile settings

An error reading any one of a number of settings from
the firmware.

An error occurred while reading

current adapter settings

Adapter setup and initialization has failed.

An error occurred while refreshing

persistent mappings

An error occurred while clearing persistent mappings.

Advanced Device Properties settings

not found

Failed to read vital configuration page from firmware.

Advanced Adapter Properties settings

not found

Failed to read vital configuration page from firmware.

Error obtaining PHY properties

configuration information

Failed to read vital configuration page from firmware.

KD534bk1.book Page 28 Monday, April 2, 2007 4:37 PM