When data being held in the print buffer, this command is ignored.
•
Regardless of the specified feed pitch, this command feeds the paper to be required to print a bar
code.
•
When the character code Dn cannot be printed, the data following after this is printed as ordinary print
data.
•
When a bar code whose number of characters to be printed is fixed has been selected,
•
the number of characters have to be always made equal to the number of characters to be printed.
•
When the horizontal direction exceeds one line length, the excess part is not printed.
(31) Selecting Bar Code width (GS
w
n)
Code : [1d]H + [77]H + N
* {2
≤
n
≤
4}
Data is described in Hex code.
Selecting bar code width.
•
The initial value of this width is "3".
(32) Selecting Bar Code Height
(GS
h
n)
Code : [1d]H + [68]H + N
* {1
≤
n
≤
FF}
Data is described in Hex code.
Selecting bar code height.
•
"n" indicates the number of dots in vertical direction.
•
The initial value of n is "162".
(33) Selecting Printing Position of HRI Characters
(GS
H
n)
Code : [1d]H + [48]H + N
* {0
≤
n
≤
3}
Data is described in Hex code.
Selecting printing position of HRI characters in printing bar codes.
•
"n" means the followings.
n (Hex)
Printing Position
0
No printing
1
Above the bar code
2
Below the bar code
3
Both above and below the bar code
•