CBM-290/291 User’s Manual

22

CITIZEN

7.5 Data receiving control

When DTR/DSR control having been selected, with BUSY signal at "LOW", data from the host side are

received.

With the signal at "HIGH", they can not be received.

When DTR/DSR control not having been selected, after X-ON transmission, data is received from the host side.

No transmission of data can take place after X-OFF is transmitted.

7.6 Buffering

Data transfer to the input buffer include DTR signals and TD signals as the control signals concerned.

(1) DTR signals (See 7.2. (2).)

(2) TXD signals (See 7.2. (3).)

7.7 Electrical characteristics

(1) RS-232C Circuit

Input (RXD, DSR)

[Printer side]

[Host side]

Output (DTR, TXD)

RXD

Mark = (

8V) : Stop bit

Space = (+8V) : Start bit

MAX 232 equivalent

Mark = (

8V) : 1

Space =(+8V) : 0

TXD

(

8V) : When busy Space

(+8V) : When ready

DTR

MAX 232 equivalent