Initial system configuration, Before you begin, Power requirements – Dell PowerEdge M600 User Manual
Page 23: Network information, Initial setup sequence, 1 unpack the enclosure and install it in a rack, 2 connect power to the power supplies
Configuration Guide
21
Initial System Configuration
Before You Begin
Power Requirements
NOTICE:
The enclosure power supplies must be connected to a Type B or
permanently-connected PDU, not directly to an electrical outlet. The power
supplies require a 200–240 V power source.
Network Information
If your network uses static addressing, you will need the IP address, subnet
mask, and gateway to configure the CMC and other modules in the enclosure.
Initial Setup Sequence
1 Unpack the enclosure and install it in a rack.
See the Getting Started Guide and Rack Installation Guide for more
information.
NOTICE:
Do not power-on the blades (server modules) until you have configured
the switch modules, as described in "Configuring the I/O Modules" on page 37.
2 Connect power to the power supplies.
NOTICE:
The power supplies must be connected to a PDU, not directly to an
electrical outlet. The power supplies require a 200–240 V power source.
3 If an optional iKVM module is installed, connect the keyboard, video, and
mouse to the enclosure control panel (see Figure 1-4) or to the iKVM
module (see Figure 1-11).
NOTE:
Connecting a keyboard, video, and mouse to the enclosure front panel
will disable video output to the iKVM back panel port.