5.1.3.2 Example Teach-in on object

The measuring range has to be taught against an object (curve 2).

Figure 3: Teach-in of output curve

In order to obtain an inverted output signal (curve 3) the distance from the sensor to the Measuring range
limit A
must be bigger than the one to the Measuring range limit B.

5.1.4

Error handling

The measuring range limits taught lie beyond the sensor’s max. measuring range (Consult sensor
specification sheet for applicable range):

Numerical Teach-in: writing of Measuring range work not possible, error message Parameter
value out of range.

Teach-in on object: measured value in Measuring range interim is set to FFFF hex, error message
Parameter value out of range. Transfer of data from the interim register to the work register is not
possible, error message Parameter value out of range.

Position the object at the start of

measuring range.

Read the measured value with

command Teach-in measuring

range limit A in the interim register

Placing the object at the end of the

measuring range

Read the measured value with

command Teach-in measuring

range limit B in the interim

register

interimregister einlesen

Transferring and activating the

measured values from interim

register to work register by the

command Transfer measuring

range

The interim register Measuring

range interim can be read at any

time for checking the teached

values

The interim register will be setting

to FFFF FFFF after transferring the

values to work register