beautypg.com

Connection, Connection cable, Pin assignment and connection diagram – Baumer BA IRxx.DxxL User Manual

Page 4: 2connection, 1 connection cable, 2 pin assignment and connection diagram

background image

en_BA_IRxx

.DxxL.docx

4/12

Baumer Electric AG

10.11.2014 14:03/simg V1.0 ANW_81146130

Frauenfeld, Switzerland

2

Connection

2.1 Connection cable

The sensors do not require a shielded cable in standard conditions. If the EMC requirements a higher a
shielded cable may be used on the connector versions of these sensors. Depending on the screening concept
the shield must be connected accordingly.

2.2 Pin assignment and connection diagram

The standard pin out for sensors with M12 connector is as follows


Check in the mounting instructions, which are delivered with each sensor, if your sensor has the same pin
configuration. In addition, the allowable supply voltage is also stated there.

ATTENTION!

The IP protection class is valid only if all connections are connected as
described in the technical documentation.

ATTENTION!

Connection, installation and commissioning may only be performed by qualified
personnel.

ATTENTION!

Incorrect supply voltage might destroy the device!

NOTE

How to connect outputs if they are not needed in an application:

teach output: connect to GND (0V)

digital output: do not connect

analog output: do not connect