Connection, Connection cable, Pin assignment and connection diagram – Baumer BA IRxx.DxxL User Manual
Page 4: 2connection, 1 connection cable, 2 pin assignment and connection diagram
en_BA_IRxx
.DxxL.docx
4/12
Baumer Electric AG
10.11.2014 14:03/simg V1.0 ANW_81146130
Frauenfeld, Switzerland
2
Connection
2.1 Connection cable
The sensors do not require a shielded cable in standard conditions. If the EMC requirements a higher a
shielded cable may be used on the connector versions of these sensors. Depending on the screening concept
the shield must be connected accordingly.
2.2 Pin assignment and connection diagram
The standard pin out for sensors with M12 connector is as follows
Check in the mounting instructions, which are delivered with each sensor, if your sensor has the same pin
configuration. In addition, the allowable supply voltage is also stated there.
ATTENTION!
The IP protection class is valid only if all connections are connected as
described in the technical documentation.
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel.
ATTENTION!
Incorrect supply voltage might destroy the device!
NOTE
How to connect outputs if they are not needed in an application:
teach output: connect to GND (0V)
digital output: do not connect
analog output: do not connect