4.2.4. Read /write offset „U“ (55h)
This command is utilized to read or write the offset that is added to the true actual value. First however the
function must be enabled in command bit parameter ‚a’ (61h).
Example 1: Read offset
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
55h
04h
26h
Example 2: Write offset
SOH
Adr
Cmd
Data (offset = –20,00)
EOT
CRC
Transmission
01h
20h
55h
2Dh
30h
32h
30h
30h
30h
04h
C3h
Response in both examples:
SOH
Adr
Cmd
Data (offset = –20,00)
EOT
CRC
Response
01h
20h
55h
2Dh
30h
32h
30h
30h
30h
04h
C3h
4.2.5. Read / write profile number „V“ (56h)
This command is utilized to read the presently active profile number or to alter the profile.
Example 1: Read active profile (active profile number = 38)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
56h
04h
20h
SOH
Adr
Cmd Profile no. = 38 EOT
CRC
Response
01h
20h
56h
33h
38h
04h
28h
Response after reset upon having cleared all profiles:
SOH
Adr
Cmd Profil-Nr. = FF
EOT
CRC
Response
01h
20h
56h
3Fh
3Fh
04h
16h
Example 2: Transmit profile (new profile number = 17)
SOH
Adr
Cmd Profile no. = 17 EOT
CRC
Transmission
01h
20h
56h
31h
37h
04h
3E
SOH
Adr
Cmd Profile no. = 17 EOT
CRC
Response
01h
20h
56h
31h
37h
04h
3E
Example 3: New profile to all N 150 by broadcast (identifier = 99 (83h); new profile number = 17)
SOH
Adr
Cmd Profile no. = 17 EOT
CRC
Transmission
01h
83h
56h
31h
37h
04h
04
Response
not confirmed
To check whether the new profile has been adopted by all N150 utilize check command „C“ (43h).