Resolution
This parameter defines the resolution of the actual value. Upon altering the resolution the decimal point is shifted
correspondingly by one digit to the right or left, same applies also to actual value and target. The target values
however are not converted correspondingly but only the decimal point is shifted. When editing the machine please
pay attention to defining the resolution first so that the target values are transmitted to the SPAs with the
corresponding resolution.
0
Resolution 1/100 mm resp. 1/1000 inch visualized in the display: 000.00 mm resp. 00.000 inch
1
Resolution 1/10 mm resp. 1/100 inch visualized in the display: 0000.0 mm resp. 000.00 inch
4.3.2. Read /write tolerance compensation and tolerance window, „b“ (62h)
This command is utilized to read or write the parameters tolerance compensation and tolerance window.
Example 1: Read parameter (tolerance compensation = 0.15; tolerance window = 0.25)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
62h
04h
48h
SOH
Adr
Cmd Tolerance compensation=0.15
Tolerance window=0.25
EOT
CRC
Response
01h
20h
62h
30h
30h
31h
35h
30h
30h
32h
35h
04h
AAh
Example 2: Write parameter (tolerance compensation = 1.30; tolerance window = 5.00)
SOH
Adr
Cmd Tolerance compensation =1.30
Tolerance window r=5.00
EOT
CRC
Transmission
01h
20h
62h
30h
31h
33h
30h
30h
35h
30h
30h
04h
20h
SOH
Adr
Cmd Tolerance compensation =1.30
Tolerance window r=5.00
EOT
CRC
Response
01h
20h
62h
30h
31h
33h
30h
30h
35h
30h
30h
04h
20h
4.3.3. Read / write spindle pitch (scaling factor) „c“ (63h)
This command is utilized to read or write the scaling factor of the spindle pitch within the range from
0,0000001...9,9999999. The decimal point is not transmitted.
How to calculate the scaling factor:
Resolution per turn: 14,40 mm
Spindle pitch:
4,00 mm
pitch 4,00
Scaling factor = ──────────── = ───── = 0,2777777
Resolution per turn 14,40
Example 1: Read scaling factor (scaling = 1.000000)
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
20h
63h
04h
4Ah
SOH
Adr
Cmd
scaling = 1.0000000
EOT
CRC
Response
01h
20h
63h
31h
30h
30h
30h
30h
30h
30h
30h
04h
4B
Example 2: Write scaling factor (scaling = 0.2777777)
SOH
Adr
Cmd
scaling = 0.2777777
EOT
CRC
Transmission
01h
20h
63h
30h
32h
37h
37h
37h
37h
37h
37h
04h
30h
SOH
Adr
Cmd
scaling = 0.2777777
EOT
CRC
Response
01h
20h
63h
30h
32h
37h
37h
37h
37h
37h
37h
04h
30h