4.4. Identifier commands
Command
code
Data amount
in bytes
read
write
Broad-
cast
Save in
EEPROM
Significance
A (41h)
2
X
X
X
X
Assign or indicate device identifier
B (42h)
2
-
-
-
-
SPA feedback in addressing mode
4.4.1. Assigning device identifiers in the network „A“ (41h)
This command is creating an automated process where the device identifier is assigned in successive order to
every single N 150 upon commissioning of the system. The first identifier to be assigned is broadcasted to all
networked N 150 as follows:
SOH
Adr
Cmd identifier = 01
EOT
CRC
Transmission
01h
83h
41h
30h
31h
04h
B4h
All N 150 now show the identifier just transmitted and that is to be assigned in the upper line of the display. The
bottom line indicates the device-specific identifier. o enter the new identifier, the shaft of the respective N 150
must be turned by at least a half (direction does not matter).The identifier is now adopted and appears in the
bottom line of the display (as device-specific identifier). Both identifiers are now identical. As soon as the shaft is
in idle position again and after having elapsed 3 seconds, N 150 will transmit to master the following
acknowledging command „B“ (42h):
SOH
Adr
Cmd identifier = 01
EOT
CRC
Transmitted
To master
01h
21h
42h
30h
31h
04h
86h
The Master may now transmits command „A“ with the next identifier to be assigned as previously described.
This way, the respective (successive) identifiers are automatically assigned to all networked N 150, one after the
other.
Important: The confirmatory command „B“ transmitted by N 150 to master will be repeated after 3 seconds
provided the master has not previously transmitted another „A“ command.
Indicate identifier in the display „A“ (41h)
This command less parameters as broadcast command (address/Identifier=99) will make every networked N
150 indicate the device-specific identifier in the bottom line of the display. The upper line is blind.
This command is a designated broadcast command.
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
83h
41h
04h
80h
Response
Not confirmed
SPA remains in this mode until being switched off and on again or until transmission of another command
except „A“, „R“, „t“ or „u“.
If this command is transmitted to a valid device identifier (except 99) without any parameters, the respective SPA
will return to standard operating mode and reply the actual device identifier.
SOH
Adr
Cmd
EOT
CRC
Transmission
01h
21h
41h
04h
0Ah
SOH
Adr
Cmd
Adr=01
EOT
CRC
Response
01h
21h
41h
30h
31h
04h
9Eh