Mounting of 3a approved products – Baumer LSKx5x User Manual
Page 4
5850-003_UK/
009-
-0
/Re
v. B
This data sheet ma
y only be reproduced in
full.
Page 4
Design and specifications subject to change without notice
Installation Manual
www.baumer.com
Mounting of 3A Approved Products
Max. ± 85°
Max. ± 75°
5)
)
)
3)
4)
Installation of 3A approved products:
) Use only a 3A approved counter part.
) The inspection hole should be visible and drained.
3) Mount the instrument in a self drained position.
4) Level the inner surface of the pipe with the counter part.
5) Weldings should be grinded to Ra= 0.8
Refer to the data sheet “Accessories” for O-rings, gaskets and other
accessories.
The LSK3x, LSK4x, LSK5x, LSK 35x and LSK 45x are approved
by 3A providing it is mounted in a 3A approved counter part and
installed according to the guidelines given in the installation manual.
The 3A approved products fulfill the FDA demands and follow the
EHEDG guidelines regarding design, materials and finishing.
Refer to the 3A marked counter parts in the data sheet “Accessories”.