Tr oubleshoo ting guide, 58mc b – Carrier 58MCB User Manual

Page 17

background image

17

Is LED status light on?

Is LED status light b

linking rapidly without a

pause?

Is LED status light b

linking ON/OFF

slo

wly

with a combination of shor

t and long flashes?

Deter

mine status code

.

The status code is a

2 digit number with the first digit deter

mined

by

the number

of shor

t flashes

and the second

digit b

y the number of long flashes?

Go to section belo

w f

or the status code that

w

as flashed.

Is there 115V at L1 and L2?

Is there 24V at SEC

-1 and SEC

-2?

Replace fur

nace control.

Chec

k f

or correct line v

oltage polarity and ground-

ing. If units are twinned, check for proper low-

voltage (24V) transformer phasing.

To

recall status code briefly remo

ve

and reconnect one RED wire from the Limi

t

Switch or Flame Rollout s

witch to displa

y stored status code

. On RED LED

control do not remo

ve po

wer or b

lo

wer access panel bef

ore initiating status

code recall.

Y

ou can also recall the pre

vious status code b

y momentar

ily shor

ting

the

TEST/TWIN ter

minal to Com24V ter

minal until the LED goes out.

LED will

flash the pre

vious status code or status code #11 (1 shor

t and 1 long flash) if

there w

as no pre

vious code

. After the control repeats the code 4 times

, the

control will go through

a br

ief component test sequenc

e.

The inducer will star

t

and r

un f

or the entire component test.

The HSI, b

lo

wer motor F

AN speed

(AMBER LED boards only) HEA

T speed, and COOL speed will r

un f

or 10 – 15

seconds each.

Gas v

alv

e and humidifier will no

t be tur

ned on.

W

as there a pre

vious status code

other than #11?

Is door s

witch closed?

Is there 115V going to s

witch?

Replace door s

witch.

Replace transf

or

mer

.

Does the control

respond to

W

, Y1

(if present),

Y/Y2, and G (24V) ther

mostat signals?

R

un system

through

a

heating

or

cooling

cycle

to chec

k operation.

Status codes are erase

d

after 72 hours

. On RED LED boards stored

status codes can also be erased whene

ve

r

(115V or 24V) is interr

upted.

Replace fur

nace control.

Close door s

witch and go bac

k to ST

A

R

T.

Is circuit break

er closed?

Chec

k f

or continuity

in wire from c

ircuit break

er

to fur

nace

.

Close circuit break

er and go bac

k to ST

A

R

T.

Chec

k room ther

mostat or

interconnecting cab

le

.

Is 24V present at

W,

Y

1 (if present),

Y/Y2 or

G ther

mostat ter

m

inals on

the

fur

nace

control?

Disconnect all the the

rmostat wires from the

fur

nace control.

Does the prob

lem repeat when using

a jumper wire?

The ther

mostat is not compatib

le with the

fur

nace

control.

Either i

nstall a

ballast resistor

,

connect the Com24V ther

mostat ter

minal to

the ther

mostat, or replace the ther

mostat.

NO

YES

YES

NO

NO

YES

YES

YES

YES

NO

YES

YES

NO

YES

NO

YES

NO

NO

NO

YES

NO

YES

NO

ST

AR

T

TR

OUBLESHOO

TING GUIDE

NO

A05107

58MC

B