4 identifier commands, Show identifier in the display „a“ (41h), Extended identifier command „ax“ (41h,58h) – Baumer N 155 User Manual
Page 13
N 155
www.baumer.com
13
4.4 Identifier
commands
4.4.1. Placing a device-specific identifier within the network „A“ (41h)
This command is for creating an automated process for defining successively the device identifier of each indi-
vidual N 155 upon commissioning of the equipment. The first device identifier to be placed is given by broadcast
command to all networked N 155 as follows:
SOH
Adr
Cmd address = 01 EOT
CRC
send
01h
83h
41h
30h
31h
04h
B4h
All N 155 will now show the identifier to be set which has just been sent in the upper line of the display. The
lower line will indicate the device-specific identifier. Push key provided at N 155 to enter the new identifier. The
identifier is entered and indicated in the lower line of the display (as new device identifier). Both identifiers are
now identical. After 3 seconds N 155 will send the following confirmation „B“ (42h) to the master:
SOH
Adr
Cmd address = 01 EOT
CRC
Send to
Master
01h
21h
42h
30h
31h
04h
86h
The Master now is able to give command „A“ with the next identifier to be placed as previously described.
This way, all N 155 in the network are automatically given the specific identifier (in successive order).
Important: The confirmation command „B“ sent by N 155 to the master will be repeated after 3 seconds in case
the master is not giving the „A“ command again.
Show identifier in the display „A“ (41h)
This command as broadcast command (Adr = 99) without any parameters will make each N 155 in the network
indicating the device-specific identifier in the bottom line of the display. The upper line is blind.
This command is a designated broadcast command.
SOH
Adr
Cmd
EOT
CRC
Send
01h
83h
41h
04h
80h
Response
no confirmation
N 155 remains in this mode until being switched off and on again or receiving another command except „A“, „R“,
„t“ or „u“.
If this command without any parameters is sent to a valid device identifier (except 99), the target display will
return to standard operation mode. The presently valid device identifier will be replied.
SOH
Adr
Cmd
EOT
CRC
Send
01h
21h
41h
04h
0Ah
SOH
Adr
Cmd
Adr=01
EOT
CRC
Response
01h
21h
41h
30h
31h
04h
9Eh
Extended identifier command „AX“ (41h,58h)
This command is for placing the individual N 155 device identifiers in a way as previously described.
The identifier to be given is sent to all N 155 in the network by the following broadcast command:
SOH
Adr
Cmd Cmd2 address = 01 EOT
CRC
Send
01h
83h
41h
58h
30h
31h
04h
40h
Similar to the standard command, the upper line of the N 155 display will show the identifier to be placed that
has just been sent. Also entering the identifier will be the same.
However, in this case NO identifier confirmation command „B“ is returned. Whether the identifier has been en-
tered or not has to be checked by master, for example by “R” command (read current value). The “R” command
is sent to the N 155 with corresponding identifier. If the identifier is entered, the target display will reply and the
master can pass on to the next identifier. Regarding other commands the N 155 display will switch to standard
operation.