4.3 Parameter commands and their significance
4.3.1 Read / write bit parameters „a“ (61h)
To exploit the maximum storage capacity, several parameters are put together and transferred as “pack”.
Parameter codes as follows:
Data1: 1 0 X X 0 0 0 0
┬ ──┬── ───┬───
│ │ └───── reserved
│ └──────────── arrows 0/1/2/3 (UP/DOWN/UNI/OFF)
└──────────────── 1
Data2: 1 0 0 X 0 X 0 0
┬ ┬ ─┬─ ─┬─ ─┬─
│ │ │ │ └─── reserved
│ │ │ └─────── turn display 0/1 (OFF/ON)
│ │ └─────────── offset 0/1 (OFF/ON)
│ └────────────── reserved
└──────────────── 1
Data3: 1 0 X X X 0 X X
┬ ┬ ──┬── ┬ ─┬─
│ │ │ │ └─── hide target 0/1/2 (ON/OFF/EVER)
│ │ │ └────── resolution 0/1 (1/100 or 1/10)
│ │ └────────── decimal point 0/1/2/3/4/5 (AUTO/OFF/0.0/0.00
│ │ 0.000/0.0000)
│ └────────────── reserved
└──────────────── 1
Data4/5: 0 0 1 1 X X X X
───┬───
└───── reserved
Important: Only bits marked ‘X’ may be altered. The fix values „1“ and „0“ must not be altered since thereby a
control token (tokens < 20h) might be created what is not allowed in ASCII protocol.
Example 1: Read bit-parameters (Data1 to Data3 = 80h; Data4 to Data5 = 30h)
SOH
Adr
Cmd
EOT
CRC
Send
01h
20h
61h
04h
4E
Bit parameter default
Example 2: Write bit parameters (positioning direction = Down; turn display = On)
SOH
Adr
Cmd Data1 Data2 Data3 Data4 Data5
EOT
CRC
Send
01h
20h
61h
81h
84h
80h
30h
30h
04h
91h
SOH
Adr
Cmd Data1 Data2 Data3 Data4 Data5
EOT
CRC
Response
01h
20h
61h
81h
84h
80h
30h
30h
04h
91h
Parameter significance
Arrows
This parameter is for displaying arrows intended as support for the editing engineer. They indicate the direction for
the new setting (clockwise or counter clockwise, up or down). The following settings are possible
00 = Up
If current value < target: arrow at the right; current value > target: arrow at the left
01 = Down
Similar to „Up“, but direction of the arrows the other way round
10 = Uni
If current value ≠ target: always indicate both arrows
11 = Off
Arrows always hidden
SOH
Adr
Cmd Data1 Data2 Data3 Data4 Data5
EOT
CRC
Response
01h
20h
61h
80h
80h
80h
30h
30h
04h
F1