Parameter commands – Baumer N 142 User Manual
Page 15
N 142
www.baumer.com
15
4.2.10. Readout any optional number sequence in the bottom line of display,
command „u“ (75h)
The command is for indicating a 6-digit number in the bottom line. The number is displayed without dot
respectively comma. Preceding zeroes as well as both direction arrows are suppressed. The upper line still
indicates the current target or number sequence.
The number sequence is displayed until any optional command except „t“, „u“ or „R“ is received by the interface.
The number will be retained after power failure.
Example: (number sequence = 123456)
SOH Adr Cmd
Number sequence = 123456
EOT CRC
Transmission
01h 20h 75h 31h 32h 33h 34h 35h 36h
04h BCh
SOH Adr Cmd
Number sequence = 123456
EOT CRC
Response
01h 20h 75h 31h 32h 33h 34h 35h 36h
04h BCh
Important:
Command “t” in conjunction with command “u” enables displaying a 12-digit number.
Both numbers are not saved in EEPROM.
4.3. Parameter commands
Command Amount of data
in Bytes
read
write
Broad-
cast
Saved in
EEPROM
Significance
a (61h)
5
X
X
-
X
Read / write general parameters
b (62h)
8
X
X
-
X
Parameter: Tolerance compensation, window
c (63h)
8
X
X
-
X
Parameter: Scaling spindle pitch
g (67h)
12
X
X
-
X
Parameter: Limits MIN, MAX
h (68h)
12
X
X
-
X
Parameter: Switching points for motor speed.
i (69h)
1
X
X
X
X
Parameter: mm / inch
j (69h)
3
X
X
X
X
Parameter: Timeout for bus error
k (6Bh)
9
X
X
-
X
Parameter: Motor system cycles
l (6Ch)
5
X
X
-
X
Parameter: Jog
m (6Dh)
5
X
X
-
X
Read / write general parameters
x (78h)
5
X
X
-
X
Read / write specific parameters