7 I/O assembly instances

The encoder supports 2 I/O assembly instances. The instance is determined by instance attribute 14
(produced_connection_path) of the connection object. The programmed value is automatically saved in the
non-volatile memory ("Save" service not necessary here).
The default value is instance 1.

The encoder supplies the following data. From the viewpoint of the master, this is input data.

Instance

Type

Name

1

Input

Position value

2

Input

Position value & Warning flag & Alarm flag



Format of I/O assembly data attributes
The I/O assembly data attributes have the following format:

Instance

Byte

Bit7

Bit6

Bit5

Bit4

Bit3

Bit2

Bit1

Bit0

1

0

Position value LSB

1

Position value

2

Position value

3

Position value MSB

2

0

Position value LSB

1

Position value

2

Position value

3

Position value MSB

4

Reserved

Warning

flag

Alarm flag



Examples:
Path for instance 1 (in hex): "20 04 24 01"
Path for instance 2 (in hex): "20 04 24 02"