beautypg.com

Terminal assignment – Baumer G1-G2-G0-GE-GB-GXxxx User Manual

Page 17

background image

Manual_DeviceNet_BIDE_EN.docx

17/18

Baumer IVO GmbH & Co. KG

22.11.12

Villingen-Schwenningen, Germany

Bus cover

– hollow shaft G0 and GB



10.2.5 Terminal assignment

Pin

Terminal

Description

Colour

M12 connector

male female

Pin 1

DRAIN

Shield connection

none

Pin 2

UB

Supply voltage 10...30 VDC

red

Pin 3

GND

Ground connection relating UB

black

Pin 4

CAN_H

CAN Bus Signal (dominant High)

white

Pin 5

CAN_L

CAN Bus Signal (dominant Low)

blue


Terminals with the same significance are internally connected and identical in their functions. Max. load on
the internal terminal connections UB-UB and GND-GND is 1 A.

Carefully plug the bus cover onto the D-SUB plug of the basic encoder, then press only via the sealing
rubber, taking care not to tilt it. The bus cover must rest fully against the basic encoder.

Tighten both the fastening screws firmly in the same direction.


The encoder housing and braided shield of the connecting cable are only ideally connected if the bus cover is
resting fully on the basic encoder (positive locking).