Baumer BA Series09 US RS232 User Manual
Page 7

Bedienungsanleitung_Series09-US_RS232_V1_e.doc
7/11
Baumer Electric AG
26.03.2013 14:43:00/tof
Frauenfeld, Switzerland
Teach-in of Sde Y
{0Y}
{0YXßß}
X
Reads and stores far limit Sde 
A: Teach-in successful 
B: No object within measuring 
range 
→
basic setting for the
sensitivity the currently set 
sensitivity level 
Write two Byte 
(identification) 
N
{0Nxx}
{0Nxxßß}
xx
Write two Bytes with any content. 
The sign must not be }. 
Read two Byte 
(identification) 
O
{0O}
{0Oxxßß}
xx
Read two Bytes stored
Get 
configuration 
V
{0V}
{0V……..ßß}
Retrieves actually saved 
configurations: 
Measuring mode (absolute, relative) 
Output format (Binary, ASCII) 
Sensor sensitivity (Sensors with 
beam columnator) 
Number of averagings 
Temperature compensation on, off 
P-code 
SW document number 
SW version 
Identification (2 Byte) 
 
See chapter „Commands explained 
in detail“ 
Set 
configuration 
U
{0U……….}
{0U……..ßß}
Configuration of sensor with a 
command: 
Measuring mode (absolute, relative) 
Output format (Binary, ASCII) 
Sensor sensitivity (Sensors with 
beam columnator) 
Number of averagings 
Temperature compensation on, off 
See chapter „Commands explained 
in detail“ 
Measuring
Single 
measurement 
M
{0M}
{0MXYxxxxßß} XYxxxx
X=1
→
Object within sensing range
X=0
→
Object not within sensing rg.
Y=1
→
Echo width big
Y=0
→
Echo width small
xxxx Measured value in sensor 
units (0…4095) or in 0.1mm steps 
 
See chapter „Commands explained 
in detail“ 
Start of 
permanent 
periodical data 
output 
P
{0P}
{0Pßß}
Provided ASCII has been selected 
the response is identical to the 
command „M“ 
 
See chapter „Commands explained 
in detail“ 
