Baumer BA Series09 US RS232 User Manual
Page 7
Bedienungsanleitung_Series09-US_RS232_V1_e.doc
7/11
Baumer Electric AG
26.03.2013 14:43:00/tof
Frauenfeld, Switzerland
Teach-in of Sde Y
{0Y}
{0YXßß}
X
Reads and stores far limit Sde
A: Teach-in successful
B: No object within measuring
range
→
basic setting for the
sensitivity the currently set
sensitivity level
Write two Byte
(identification)
N
{0Nxx}
{0Nxxßß}
xx
Write two Bytes with any content.
The sign must not be }.
Read two Byte
(identification)
O
{0O}
{0Oxxßß}
xx
Read two Bytes stored
Get
configuration
V
{0V}
{0V……..ßß}
Retrieves actually saved
configurations:
Measuring mode (absolute, relative)
Output format (Binary, ASCII)
Sensor sensitivity (Sensors with
beam columnator)
Number of averagings
Temperature compensation on, off
P-code
SW document number
SW version
Identification (2 Byte)
See chapter „Commands explained
in detail“
Set
configuration
U
{0U……….}
{0U……..ßß}
Configuration of sensor with a
command:
Measuring mode (absolute, relative)
Output format (Binary, ASCII)
Sensor sensitivity (Sensors with
beam columnator)
Number of averagings
Temperature compensation on, off
See chapter „Commands explained
in detail“
Measuring
Single
measurement
M
{0M}
{0MXYxxxxßß} XYxxxx
X=1
→
Object within sensing range
X=0
→
Object not within sensing rg.
Y=1
→
Echo width big
Y=0
→
Echo width small
xxxx Measured value in sensor
units (0…4095) or in 0.1mm steps
See chapter „Commands explained
in detail“
Start of
permanent
periodical data
output
P
{0P}
{0Pßß}
Provided ASCII has been selected
the response is identical to the
command „M“
See chapter „Commands explained
in detail“