Baumer BA Series09 US RS232 User Manual
Page 11
Bedienungsanleitung_Series09-US_RS232_V1_e.doc
11/11
Baumer Electric AG
26.03.2013 14:43:00/tof
Frauenfeld, Switzerland
Teach-in of SDC
{0X}
{0XA01}
Teach-in successful, the
present object position is
stored as SDC
Teach-in of SDE
{0Y}
{0YB03}
Teach-in not successful,
Teach-in range as
defined in the factory
settings is downloaded
Get Configuration
{0V}
{0VBADC1A1218110
27010000ab53}
Configuration:
B: relative measurement
A: ASCII for periodical
measurements
D: highest sensitivity
C: 4 times averaged
1: Temperature
compensation ON.
A121: P-Code
811027: SW doc no
010000: SW Version
ab: Identification
52: Check sum
Set configuration
{0UABAF0} {0UABAF047}
Configuration:
A: absolute
measurement
B: Binary for periodical
measurement
A: lowest sensitivity
F: 32 averagings
0: temperature
compensation OFF
47: Check sum
Write 2 Byte(Identification)
{0N01}
{0N0123}
01 written to the sensor
Read 2 Byte (Identification)
{0O}
{0O0124}
01 read from the sensor
Single measurement
{0M}
{0M11140121}
1: Object within range
1: Echo width big
1401: measured value
Start permanent periodical
data output
{0P}
{0P28}
This is the first answer,
data follows suit
Error messages (examples)
Error
Sent
Received
Explanation
Wrong address
{3M}
{0EA82}
A = Wrong address
Temperature compensation ON
sent with wrong parameter (3
instead of 1)
{0G3}
{0EP97}
P = impermissible
parameter
Wrong command
{0W}
{0EU02}
U = unknown command
EOF forgotten
{0M
{0ET01}
T = after SOF before
EOF more than 0.5s
distance between 2
characters
One ‚0’ too many
{0M0}
{0EF87}
F = Framing error =
wrong string length