Configuration

Load factory
settings

D

{0D}

{0Dßß}

The Sensor is configured with its
factory settings.
See chapter „Factory
configurations“

Set measuring
mode

A

{0AX}

{0AXßß}

X

A: absolute measurement in 0.1mm
steps
B: relative measurement within the
Teach-range 0…4096
See chapter „Commands explained
in detail“

Set output
format of
permanent
periodical data
output

F

{0FX}

{0FXßß}

X

A: ASCII
B: Binary

See chapter „Commands explained
in detail“

Set sensor
sensitivity
(Sensors with
beam
columnator)

B

{0BX}

{0BXßß}

X

A: Highest sensitivity
Measuring into test tubes
Measuring range: 3…150 mm
B: Second highest sensitivity
Measuring into plates size 96 with
big hole diameter
Measuring range: 3…110 mm
C: Second lowest sensitivity
Measuring into plates size 96 with
small hole diameter
Measuring range: 3…70 mm
D: Lowest sensitivity
Measuring into plates size 384
Measuring range 3…30 mm
See chapter „Commands explained
in detail“

Set number of
averagings

C

{0CX}

{0CXßß}

X

A: not averaged
B: 2
C: 4
D: 8
E: 16
F: 32
G: 64
See chapter „Commands explained
in detail“

Temperature
compensation
on, off

G

{0Gx}

{0Gxßß}

x

0: Temperature compensation off
1: Temperature compensation on

See chapter „Commands explained
in detail“

Teach-in of Sdc X

{0X}

{0XXßß}

X

Reads and stores close limit Sdc
A: Teach-in successful
B: No object within measuring
range

basic setting for the

sensitivity the currently set
sensitivity level