7. Encoder configuration
The encoder-specific parameters can be programmed by the parameter object 0Fh. Each object entity
refers to
a certain attribute of the encoder-position-objects.
Amended parameters are not stored in the non-volatile memory until the service „save“ is carried out.
Parameter object entities
The following chart shows the parameter object 0Fh entities supported by the encoder.
Entity No.
name
Reference to attribute no. of the
Encoder Position Object 2Fh
1
Sense of rotation
3
2
internal diagnostic function (not used)
4
3 Scaling
function
5
4 Position
format
6
5
Steps per revolution
7
6
Total resolution in steps
8
7
Measurement steps (not used)
9
8 Preset
value
10
9 Position
value
12
10 Operating
status
80
11 Singleturn
resolution
81
12
Number of revolutions
82
13 Alarm
flag
85
14 Alarm
signals
83
15
Supported alarm signals
84
16 Warn
flag
88
17 Warning
signals
86
18
Supported warning signals
87
19
Profile / Software version
89
General services
The parameter object supports the following services:
Code
Service
Signifcance
0Eh Get_Attribute_Single
Provides
the
content of the selected attribute
10h
Set_Attribute_Single
Changes the value of the selected attribute.
The new value is not yet (!) stored in the non-
volatile memory
05h
Reset
Resets all parameters to default
15h
Restore
Restores all parameters of the non-volatile memory
16h
Save
Saves all parameters in the non-volatile memory to
be restored after mains on/off