beautypg.com

Baumer GXP8W User Manual

Page 13

background image

Manual_GXP8W_EN.doc

13/13

Baumer IVO GmbH & Co. KG

04.05.11

Villingen-Schwenningen,

Germany

9.2.3. Terminal significance

Pin

Terminal

Significance

1

DRAIN Shield

connection

2

UB

Power supply 10...30 VDC

3

GND B

Ground connection UB

4

CAN_H

CAN Bus Signal (dominant High)

5

CAN_L

CAN Bus Signal (dominant Low)

Micro Connector
Pinout
Male (Pin)



9.3. Display elements (status display)

A DUO LED (green/red) working in the ‘Combined Module/Network Status’ in line with the DeviceNet
specification is providing information on the status of the device respectively of the network.

LED-Colour

Status

Significance

off not

connected

No power supply

- Dupl. MAC-ID check not terminated.
- No power supply

Green flashing

Device is active and online
No connections established

The device is operating under normal conditions and
is online, no connection established.

- Encoder not yet configurated by Master

- configuration incomplete or faulty

Green continous Device is active and online

Connections are established

The device is operating under normal conditions and
is online, connection status “established”

Red continous

Critical device error or
Critical communication error

The device is in fatal non-corrective error status

- no network communication possible
- double assignment of user address (MAC-ID)

Red flashing

Corrective error

I/O connections in Time-Out status