9.2.3. Terminal significance
Pin
Terminal
Significance
1
DRAIN Shield
connection
2
UB
Power supply 10...30 VDC
3
GND B
Ground connection UB
4
CAN_H
CAN Bus Signal (dominant High)
5
CAN_L
CAN Bus Signal (dominant Low)
Micro Connector
Pinout
Male (Pin)
9.3. Display elements (status display)
A DUO LED (green/red) working in the ‘Combined Module/Network Status’ in line with the DeviceNet
specification is providing information on the status of the device respectively of the network.
LED-Colour
Status
Significance
off not
connected
No power supply
- Dupl. MAC-ID check not terminated.
- No power supply
Green flashing
Device is active and online
No connections established
The device is operating under normal conditions and
is online, no connection established.
- Encoder not yet configurated by Master
- configuration incomplete or faulty
Green continous Device is active and online
Connections are established
The device is operating under normal conditions and
is online, connection status “established”
Red continous
Critical device error or
Critical communication error
The device is in fatal non-corrective error status
- no network communication possible
- double assignment of user address (MAC-ID)
Red flashing
Corrective error
I/O connections in Time-Out status