Bio-Rad DCode™ Universal Mutation Detection System User Manual
Page 87

Section 13
Systems, Accessories, and Reagents for Mutation
Detection Electrophoresis
For complete ordering information for DCode accessories, electrophoresis reagents, and
control kits, request bulletin 2100.
Catalog
Number
Product Description
DCode Universal Mutation Detection Systems
170-9080
DCode System for DGGE, 16 cm, 120 V, includes electrophoresis/
temperature control module, sandwich core, DGGE kit for 16 cm gel casting
(2 sets of plates, 2 sets of clamps and 1 mm spacers, two 1 mm one well
prep combs, comb gasket), all parts required to cast gradient gels, Model
475 Gradient Former, control reagents for DGGE
170-9081
DCode System for DGGE, 16 cm, 220/240 V
170-9082
DCode System for DGGE, 16 cm, 100 V
170-9083
DCode System for DGGE, 10 cm, 120 V, includes electrophoresis/
temperature control module, sandwich core, DGGE kit for 10 cm gel casting
(2 sets of plates, 2 sets of clamps and 1 mm spacers, two 2-well 1 mm
prep combs, comb gasket), all parts required to cast gradient gels, Model
475 Gradient Former, control reagents for DGGE
170-9084
DCode System for DGGE, 10 cm, 220/240 V
170-9085
DCode System for DGGE, 10 cm, 100 V
170-9086
DCode System for CDGE, 120 V, includes electrophoresis/temperature
control module, sandwich core, CDGE kit for 16 cm gel casting (2 sets of 16 cm
plates, 2 sets of 1 mm spacers, two 20-well 1 mm combs), control reagents
for CDGE
170-9087
DCode System for CDGE, 220/240 V
170-9088
DCode System for CDGE, 100 V
170-9089
DCode System for TTGE, 120 V, includes electrophoresis/temperature
control module, sandwich core, TTGE kit for 16 cm gel casting (2 sets of
16 cm plates, 2 sets of 1 mm spacers, two 20-well 1 mm combs), control
reagents for TTGE
170-9090
DCode System for TTGE 220/240 V
170-9091
DCode System for TTGE 100 V
170-9092
DCode System for SSCP, 120 V, includes electrophoresis temperature
control module, sandwich core, SSCP kit for gel casting (2 sets of 20 cm
plates, 2 sets 0.75 mm spacers, two 20-well 0.75 mm thick combs), elec-
trophoresis cooling tank for use with external cooling bath, control reagents
for SSCP
170-9093
DCode System for SSCP, 220/240 V
170-9094
DCode System for SSCP, 100 V
170-9095
DCode System for Heteroduplex Analysis, 120 V, includes electrophoresis/
temperature control module, sandwich core, heteroduplex kit for gel casting
(2 sets of 20 cm plates, 2 sets of 0.75 mm spacers, two 20-well 0.75 mm thick
combs), control reagents for heteroduplex analysis
170-9096
DCode System for Heteroduplex Analysis, 220/240 V
83