Adjustments

Cleaning Out Meters
NOTE: Shut off sliding seed tubes before at-
tempting to clean out seed meters.

Refer to Figure 34

For seed meter clean out:

1.

Position tarp or buckets under the opener(s)
whose meter(s) you will be cleaning out.

2.

Remove retaining clip and pull pin.

Refer to Figure 35

3.

Pull up on meter clean out door to open.

Refer to Figure 36

4.

When meter is empty, push meter clean out
door back to its original position to close.

NOTE: You may need to shake the clean out
door a little before closing to make sure all
seeds fall out.

5.

Replace pin and retaining clip.

Figure 34

Meter clean out

18261

Retaining clip

Clean out door

Figure 35

Meter clean out door

19190

Clean out door

Figure 36

Replacing pin

19192

Clean out door