System operation, Operator’s manual, Start – Great Plains DICKEY-john IntelliAg Planter-Drill Control L1 User Manual
Page 9: Stop
OPERATOR’S MANUAL
IntelliAg PDC User Level 1 (GP)
11001-1508-200903
SYSTEM OPERATION / 7
SYSTEM OPERATION
START
1. Lower the implement to operating position engaging the implement
switch, if present and enabled.
2. With the hydraulic system engaged and the tractor at its normal
operating RPM, set the master switch to the On position. All enabled
control channels will begin controlling at the current ground speed. All
accumulators will begin recording data.
When the implement is down and the master switch is in the On
position, the machine is fully operational. All necessary
precautions must be taken to ensure user safety. Failure to
practice all necessary caution may result in serious injury or
death.
STOP
1. Set the master switch to the Off position. All control channels will
cease operation and all data accumulation will halt.
2. Operation will immediately stop when the ground speed is 0 or when
the implement is raised.
Figure 4
Main Work Screen Functions
300
Target Rate
Inc/Dec %
Target Rate
Preset Enabled
Accumulator
Reset
Implement Lift
Up/Down
Indicator
Row
Indicators