START

1. Lower the implement to operating position engaging the implement

switch, if present and enabled.

2. With the hydraulic system engaged and the tractor at its normal

operating RPM, set the master switch to the On position. All enabled
control channels will begin controlling at the current ground speed. All
accumulators will begin recording data.

When the implement is down and the master switch is in the On
position, the machine is fully operational. All necessary
precautions must be taken to ensure user safety. Failure to
practice all necessary caution may result in serious injury or
death.

STOP

1. Set the master switch to the Off position. All control channels will

cease operation and all data accumulation will halt.

2. Operation will immediately stop when the ground speed is 0 or when

the implement is raised.

Figure 4
Main Work Screen Functions

300

Target Rate

Inc/Dec %

Target Rate

Preset Enabled

Accumulator
Reset

Implement Lift
Up/Down
Indicator

Row
Indicators