Lubrication storage, Pto pump {if applicable, Universal lubrication symbols – Great Plains TM700 Operator Manual User Manual

Page 58

background image

Tractor Mount Sprayer

500-052M

5/13/2003

56

PTO Pump {if applicable}

The grease zerk is located on the gear case cover and is
marked with a decal. Grease with five shots of grease.

Type of Lubrication: NLGI grade 2 or 3 grease lubricant

12229

10

Lubrication

Storage

1.

Empty solution from the tank and store or dispose of
the chemical as recommended by the manufactur-
er’s chemical label.

2.

Flush the entire sprayer system with clean water.

3.

Clean out Whirlfilters

®

. Refer to "Operating Whirl-

filter

®

" on Page 26.

4.

Circulate 3 - 5 gallons of antifreeze {Great Plains
strongly recommends the use of recreational vehicle
antifreeze} through the system including the pump,
hoses and nozzles. Drain the sprayer and properly
dispose of antifreeze.Keep antifreeze in the pump to
prevent gasket shrinkage.

Note: Regular antifreeze is harmful or fatal to animals
and humans. Use carefully according to the label’s in-
structions. We strongly recommend the use of recre-
ational vehicle antifreeze which does not exhibit these
harmful side effects.

5.

Remove nozzles, disconnect the control box, and
place them indoors.

6.

Change filters in the tractor cab after finished.

7.

Wash off the exterior of the sprayer thoroughly using
a safe solvent or soap and water.

8.

Inspect all parts of the sprayer for wear and rust. Re-
pair and paint parts as necessary.

9.

Store the sprayer in a dry area away from direct sun-
light.

Use a multipurpose spray lub. Use as required.

Do not over lubricate.

As

Required

Seasonally

Lubrication is required ______________.

Lubrication is required every 10 hours of operation.

Universal Lubrication Symbols

10

Lubrication is required every 10 hours of operation.

10