beautypg.com

Worn nozzles & flow table information – Great Plains TM700 Operator Manual User Manual

Page 32

background image

Tractor Mount Sprayer

500-052M

5/13/2003

30

Worn Nozzles & Flow Table
Information

1.

Determine nozzle size and desired spraying pres-
sure using this application guide.

2.

Find fluid ounces per minute (OPM) in Table #3 or
Table #4.

3.

Catch flow at pressure desired for 1 minute {for large
nozzles catch the flow for 30 seconds and multiply
by 2}.

4.

If the OPM caught are within the

+

limit in the chart

on page 31, the nozzle is accurate and G.P.A. charts
should be followed.

5.

If the nozzle is not within the

+

limit, check for ob-

structions or wear in the orifices of the nozzle. Take
the cap off the nozzle, clean the orifices with a tooth-
pick or brush and retest. If several nozzles test the
same, but are not within the

+

limits, a faulty gauge

may be the problem. If two or more nozzles are out-
side the limit, it is a good indication that all your noz-
zles may be worn. In this case, it would be advisable
to replace ALL the nozzles with new nozzles.

6.

FOR HEAVIER SOLUTIONS USE DENSITY FLOW
CONVERSION TABLE ON PAGE 32.