Two t – Wheatheart X13 Power Swing User Manual
Page 28

5. A
PPENDIX
W
HEATHEART
- P
OWER
S
WING
M
ANUAL
5.1. R
EMOTE
T
RANSMITTER
I
NSTRUCTIONS
E
LECTRIC
AND
H
YDRAULIC
28
30802 R0
T
O
R
EGISTER
TWO T
RANSMITTERS
TO
A
R
ECEIVER
:
1. Switch OFF or disconnect the power to the receiver.
2. Switch ON or reconnect the power to the receiver. This opens a 20 second
registration window in the receiver processor.
3. Immediately PRESS and HOLD the RESET button on the FIRST transmitter
(see Figure 5.2) for a minimum of 5 seconds or until the FAULT LED
illuminates.
4. The FAULT LED will stay on for 2 seconds. RELEASE the RESET button on
the FIRST transmitter during this 2 second period.
5. The FAULT LED will start to flash again. PRESS and HOLD the RESET
button on the SECOND transmitter for 5 seconds or until the SET LED
illuminates. Both transmitters should now operate the receiver.
Note:
To clear all codes from transmitter, hold down the red stop button for at least 45
seconds.