Sftymute - safety mute, Siggen - signal generator, Argument details – ClearOne XAP 800 User Manual
Page 131: Appendices ~ appendix e: serial commands

125
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
SFTYMUTE - Safety mute
Selects/reports the state of the safety mute. When on, the safety mute holds all
outputs on the selected unit in a muted state. It is used primarily for troubleshooting
G-Ware.
Command form: DEVICE SFTYMUTE [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
SFTYMUTE
Command
Value
0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#52 SFTYMUTE 1 On XAP 800 unit 2 (#52), safety mute
(SFTYMUTE) is enabled (1).
SIGGEN - Signal Generator
This command selects/reports of the signal generator activation.
Command form:
DEVICE
SIGGEN
[Frequency]
Argument details
Name
Description
Device
0–7 or * to select all units
SIGGEN
Command
Channel
See Groups and Channels, page 97
Group
I, M, L
Type
0 = Off, 1 = Pink, 2 = White, 3 = Tone, Null = Current state
Amplitude
-60 to +20 amplitude in dB; NULL for type 0
Frequency
20 to 20,000 frequency in Hz (only needed when using tone
generation)
Example:
#56 SIGGEN 1 M 2 0 On XAP 800 unit 6 (#56), the signal gen-
erator (SIGGEN) is set to input at mic (M) channel 1 with white noise (2) at 0dB.
Appendices
~ Appendix E: Serial Commands