Appendices
~ Appendix E: Serial Commands
104
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
DFLTM - Default Meter
This command selects/reports the setting of the default meter.
Command form: DEVICE DFLTM [Channel] [Group] [Position]
Argument details
Name
Description
Device
0–7 or * to select all units
DFLTM
Command form
Channel
1–12
Group
I = Inputs, O = Outputs, M = Mic Inputs, L= Line Inputs
Position
I, A, N, G, as applicable for group
(see Meter Type definitions, page 98)
Example:
#55 DFLTM 8 O A On XAP 800 unit 5 (#55), the default meter
(DFLTM) is set to output (O) 8 after the gain adjustment (A).
DID - Device ID
This command selects/reports the device ID.
Command form:
DEVICE DID [Value]
Argument details
Name
Description
Device
0–7 or * to select all units
DID
Command form
Value
0–7 (select device ID)
Example:
#57 DID 0 On XAP 800 unit 7 (#57), the device ID (DID) is set to 0.
DSPVER - DSP Version
This command reports the version of the DSP code in the unit. the version is a date
and time stamp. This command is read only.
Command form: DEVICE DSPVER [value]
Argument details
Name
Description
Device
0–7 or * to select all units
DSPVER
Command form
Value
Null
Example
: #55 DSPVER The XAP 800 unit 5 (#55) will return the DSP version
(DSPVER).