beautypg.com

Primary harness (h1),wire connection guide – Clarion SR5000 User Manual

Page 6

background image

7

Primary Harness (H1),Wire Connection Guide

Primary Harness (H1) Wiring Diagram

___

___

___

___

___

___

___

___

___

___

___

___

Primary Harness Wire Descriptions

H1/1 ORANGE (-) Ground-When-Armed Output
This wire supplies a (-) 500 mA ground as long as the system is armed. This output ceases as soon
as the system is disarmed. The orange wire is pre-wired to control the starter kill relay.

N

NO

OTTEE:: If using the H1/1 ORANGE wire to activate an add-on accesso-

ry such as window automation, pager or voice module a 1 Amp diode
must be installed to ensure proper operation. Insert the diode as shown in
the following diagram.

IMPORTANT! Never interrupt any wire other than the starter wire.

RED/WHITE

(-) 200 mA Channel 2 Output

RED

(+) Constant Power Input

BROWN

(+) Siren Output

OPEN

No Wire

BLACK

(-) Chassis Ground Input

VIOLET

(+) Door Trigger Input, Zone 3

BLUE

(-) Multiplexed Input, Zone 4

GREEN

(-) Door Trigger Input, Zone 3

BLACK/WHITE

(-) 200 mA Domelight Supervision Output

WHITE/BLUE

(-) Remote Start Activation Input

WHITE

(+)/(-) Selectable Light Flash Output

ORANGE

(-) 500 mA Armed Output

H1/1

H1/2

H1/3

H1/4

H1/5

H1/6

H1/7

H1/8

H1/9

H1/10

H1/11

H1/12